Spinner Results
AJAX DPC600 Integral Gas Compressor
A dedicated electric motor driven pump powers the Spinner centrifuge to clean the sump oil of this splash fed compressor

The patch test
shows the Spinner advantage!
There are two slides of the SAME oil, however they are NOT in the order you'd expect. These slides are 8 micron test patches from an AJAX integral gas compressor. The left patch is the oil about three weeks before the addition of a Spinner II centrifuge. The right patch is the result after two weeks of cleanup by the Spinner II centrifuge.

NOTE:
The left patch blocked the flow of oil after 30ml of the desired 40ml had been drawn through it. The right patch has the desired 40ml of sample, NO BLOCKING. A comparison of color intensity can be made to compare the relative cleanliness of the two oils, but remember the patch result on the right would be lighter by 25% if 30ml instead of 40ml had been drawn through it, making this comparison even more telling!